MVA_C1
Ventilatore
Tipo
MVA220C1
MVA280C1
MVA360C1
MVA450C1
MVA500C1
Prestazioni in ra
ffrescamento nominal
i
Potenza frigorifera (1)
kW
2,20
2,80
3,60
4,50
5,0
0
Prestazioni in riscaldamento nominal
i
Potenza termica (2)
kW
2,50
3,20
4,00
5,00
5,6
0
Dati elettrici
Potenza nominale assorbita (3)
W
30
30
30
30
30
tipo
Tangenziale inverter
Tangenziale inverter
Tangenziale inverter
Tangenziale inverter
Tangenziale inverte
r
m³/h
450
450
450
500
500
m³/h
500
500
500
600
60
0
Massima
m³/h
600
600
600
830
83
0
Portata d’aria
Minima
Media
Potenza sonora (4
)
Minima
Media
Massima
Pressione sonora (5)
Minima
Media
dB(A)
38,0
38,0
38,0
40,0
40,
0
dB(A)
42,0
42,0
42,0
45,0
45,0
dB(A)
46,0
46,0
46,0
50,0
50,0
dB(A)
28,0
28,0
28,0
30,0
30,
0
dB(A)
32,0
32,0
32,0
35,0
35,0
dB(A)
36,0
36,0
36,0
40,0
40,0
Diametro attacchi frigoriferi liquido
mm (inch)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”
)
Diametro attacchi frigoriferi gas
mm (inch)
9,52 (3/8”)
9,52 (3/8”)
12,7 (1/2”)
12,7 (1/2”)
12,7 (1/2”
)
Alimentazion
e
Alimentazione unità interna
220-240V ~ 50Hz
220-240V ~ 50Hz
220-240V ~ 50Hz
220-240V ~ 50Hz
220-240V ~ 50H
z
Massima
Tubazioni frigorifere
Unità intern
a
Diametro scarico condensa
mm
25,0
25,0
25,0
25,0
25,
0
(1)
(2)
(3)
(4)
(5)
Ra
ffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m
.
La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744
.
Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.
MVA_F
MVA281F
MVA361F
MVA501F
MVA561F
MVA631F
MVA711F
MVA901F MVA1121F MVA1251F MVA1401F MVA1601
F
Prestazioni in raffrescamento nominal
i
Potenza frigorifera (1)
Prestazioni in riscaldamento nominali
Potenza termica (2)
Dati elettrici
Ventilatore
kW
2,80
3,60
5,00
5,60
6,30
7,10
9,00
11,20
12,50
14,00
16,00
kW
3,20
4,00
5,60
6,30
7,10
8,00
10,00
12,50
14,00
16,00
18,0
0
Potenza nominale assorbita (3)
W
35
35
55
55
80
80
120
120
120
150
175
Tipo
tipo
Centrifug
o
inverte
r
Centrifug
o
inverte
r
Centrifugo
inverter
Centrifug
o
inverte
r
Centrifugo
inverter
Centrifugo
inverte
r
Centrifugo
inverte
r
Centrifug
o
inverter
Centrifug
o
inverte
r
Centrifug
o
inverte
r
Centrifugo
inverter
Portata d’ari
a
Minima
Media
Massima
m³/h
450
450
600
600
1.050
1.050
1.250
1.400
1.400
1.600
1.65
0
m³/h
500
500
650
650
1.200
1.200
1.400
1.600
1.600
1.750
1.85
0
m³/h
600
600
750
750
1.350
1.350
1.550
1.800
1.800
2.000
2.150
Potenza sonora (4
)
Minima
Media
Massima
dB(A)
45,0
45,0
48,0
48,0
54,0
54,0
54,0
54,0
54,0
55,0
57,
0
dB(A)
48,0
48,0
51,0
51,0
57,0
57,0
56,0
56,0
56,0
57,0
60,0
dB(A)
52,0
52,0
54,0
54,0
60,0
60,0
59,0
59,0
59,0
61,0
64,0
Pressione sonora (5)
Minima
Media
Massima
dB(A)
29,0
29,0
36,0
36,0
38,0
38,0
41,0
42,0
42,0
43,0
45,0
dB(A)
32,0
32,0
39,0
39,0
41,0
41,0
44,0
44,0
44,0
45,0
48,0
dB(A)
36,0
36,0
42,0
42,0
44,0
44,0
47,0
47,0
47,0
49,0
52,0
Tubazioni frigorifere
Diametro attacchi frigoriferi liquido
mm (inch)
6,35 (1/4”) 6,35 (1/4”) 6,35 (1/4”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”
)
Diametro attacchi frigoriferi gas
mm (inch)
9,52 (3/8”) 12,7 (1/2”) 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 19,05 (3/4”)
Alimentazion
e
Alimentazione unità interna
220-240V ~
50Hz
220-240V
~
50H
z
220-240V ~
50H
z
220-240V ~
50H
z
220-240V
~
50H
z
220-240V ~
50H
z
220-240V ~
50Hz
220-240V
~
50H
z
220-240V ~
50Hz
220-240V ~
50H
z
220-240V
~
50H
z
Unità intern
a
Diametro scarico condensa
mm
17,0
17,0
17,0
17,0
17,0
17,0
17,0
17,0
17,0
17,0
17,0
(1)
(2)
(3)
(4)
(5)
Ra
ffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m
.
La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744
.
Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale
.
S
I
S
T
E
M
I
V
R
F
MVBM_I_UN50_0
5
www.aermec.com
1037