MVA_C

MVA221C

MVA281C

MVA361C

MVA451C

MVA501C

MVA561C

MVA631

C

Prestazioni in ra

ffrescamento nominali

Potenza frigorifera (1)

kW

2,20

2,80

3,60

4,50

5,00

5,60

6,30

Prestazioni in riscaldamento nominali

Potenza termica (2)

kW

2,50

3,20

4,00

5,00

5,60

6,30

7,1

0

Dati elettric

i

Potenza nominale assorbita (3)

W

26

26

26

26

28

35

60

Ventilator

e

Tipo

tipo

Centrifugo inverter

Centrifugo inverter

Centrifugo inverter

Centrifugo inverter

Centrifugo inverter

Centrifugo inverter

Centrifugo inverter

Portata d’aria

Minima

Media

Massima

m³/h

600

600

600

600

700

750

850

m³/h

700

700

700

700

800

850

95

0

m³/h

800

800

800

800

900

950

1.15

0

Potenza sonora (4

)

Minima

Media

Massima

dB(A)

42,0

42,0

42,0

42,0

43,0

44,0

45,

0

dB(A)

44,0

44,0

44,0

44,0

46,0

47,0

48,0

dB(A)

47,0

47,0

47,0

48,0

49,0

51,0

51,0

Pressione sonora (5

)

Minima

Media

Massima

dB(A)

28,0

28,0

28,0

28,0

29,0

30,0

31,0

dB(A)

30,0

30,0

30,0

30,0

32,0

33,0

34,

0

dB(A)

33,0

33,0

33,0

34,0

35,0

37,0

37,0

Tubazioni frigorifere

Diametro attacchi frigoriferi liquido

mm (inch)

6,35 (1/4”)

6,35 (1/4”)

6,35 (1/4”)

6,35 (1/4”)

6,35 (1/4”)

9,52 (3/8”)

9,52 (3/8”)

Diametro attacchi frigoriferi gas

mm (inch)

9,52 (3/8”)

9,52 (3/8”)

12,7 (1/2”)

12,7 (1/2”)

12,7 (1/2”)

15,9 (5/8”)

15,9 (5/8”)

Alimentazione

Alimentazione unità interna

220-240V ~ 50Hz

220-240V ~ 50Hz

220-240V ~ 50Hz

220-240V ~ 50Hz

220-240V ~ 50Hz

220-240V ~ 50Hz

220-240V ~ 50Hz

Unità interna

Diametro scarico condensa

mm

25,0

25,0

25,0

25,0

25,0

25,0

25,

0

(1)

(2)

(3)

(4)

(5)

Ra

ffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m

.

Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m

.

La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40

.

Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744

.

Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale

.

MVA711C

MVA801C

MVA901C

MVA1001C

MVA1121C

MVA1251C

MVA1401C

MVA1601

C

Prestazioni in raffrescamento nominali

Potenza frigorifera (1)

kW

7,10

8,00

9,00

10,00

11,20

12,50

14,00

16,00

Prestazioni in riscaldamento nominal

i

Potenza termica (2)

kW

8,00

9,00

10,00

11,20

12,50

14,00

16,00

18,0

0

Dati elettric

i

Potenza nominale assorbita (3)

W

60

85

85

85

115

115

115

170

Ventilatore

Tipo

tipo

Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverte

r

Portata d’aria

Minima

Media

Massima

m³/h

850

900

900

900

1.100

1.100

1.100

1.43

0

m³/h

950

1.000

1.000

1.000

1.300

1.300

1.300

1.800

m³/h

1.150

1.250

1.250

1.250

1.650

1.650

1.650

2.00

0

Potenza sonora (4)

Minima

Media

Massima

dB(A)

45,0

48,0

48,0

48,0

53,0

53,0

53,0

54,0

dB(A)

48,0

51,0

51,0

51,0

55,0

55,0

55,0

60,0

dB(A)

51,0

53,0

53,0

53,0

57,0

57,0

57,0

63,0

Pressione sonora (5

)

Minima

Media

Massima

dB(A)

31,0

34,0

34,0

34,0

39,0

39,0

39,0

42,

0

dB(A)

34,0

37,0

37,0

37,0

41,0

41,0

41,0

48,

0

dB(A)

37,0

39,0

39,0

39,0

43,0

43,0

43,0

51,0

Tubazioni frigorifere

Diametro attacchi frigoriferi liquido

mm (inch)

9,52 (3/8”)

9,52 (3/8”)

9,52 (3/8”)

9,52 (3/8”)

9,52 (3/8”)

9,52 (3/8”)

9,52 (3/8”)

9,52 (3/8”)

Diametro attacchi frigoriferi gas

mm (inch)

15,9 (5/8”)

15,9 (5/8”)

15,9 (5/8”)

15,9 (5/8”)

15,9 (5/8”)

15,9 (5/8”)

15,9 (5/8”)

19,05 (3/4”)

Alimentazion

e

Alimentazione unità interna

220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50H

z

Unità interna

Diametro scarico condensa

mm

25,0

25,0

25,0

25,0

25,0

25,0

25,0

25,0

(1)

(2)

(3)

(4)

(5)

Ra

ffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.

Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m

.

La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.

Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744

.

Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.

S

I

S

T

E

M

I

V

R

F

1036

www.aermec.com

MVBM_I_UN50_05