MVA_C
MVA221C
MVA281C
MVA361C
MVA451C
MVA501C
MVA561C
MVA631
C
Prestazioni in ra
ffrescamento nominali
Potenza frigorifera (1)
kW
2,20
2,80
3,60
4,50
5,00
5,60
6,30
Prestazioni in riscaldamento nominali
Potenza termica (2)
kW
2,50
3,20
4,00
5,00
5,60
6,30
7,1
0
Dati elettric
i
Potenza nominale assorbita (3)
W
26
26
26
26
28
35
60
Ventilator
e
Tipo
tipo
Centrifugo inverter
Centrifugo inverter
Centrifugo inverter
Centrifugo inverter
Centrifugo inverter
Centrifugo inverter
Centrifugo inverter
Portata d’aria
Minima
Media
Massima
m³/h
600
600
600
600
700
750
850
m³/h
700
700
700
700
800
850
95
0
m³/h
800
800
800
800
900
950
1.15
0
Potenza sonora (4
)
Minima
Media
Massima
dB(A)
42,0
42,0
42,0
42,0
43,0
44,0
45,
0
dB(A)
44,0
44,0
44,0
44,0
46,0
47,0
48,0
dB(A)
47,0
47,0
47,0
48,0
49,0
51,0
51,0
Pressione sonora (5
)
Minima
Media
Massima
dB(A)
28,0
28,0
28,0
28,0
29,0
30,0
31,0
dB(A)
30,0
30,0
30,0
30,0
32,0
33,0
34,
0
dB(A)
33,0
33,0
33,0
34,0
35,0
37,0
37,0
Tubazioni frigorifere
Diametro attacchi frigoriferi liquido
mm (inch)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
9,52 (3/8”)
9,52 (3/8”)
Diametro attacchi frigoriferi gas
mm (inch)
9,52 (3/8”)
9,52 (3/8”)
12,7 (1/2”)
12,7 (1/2”)
12,7 (1/2”)
15,9 (5/8”)
15,9 (5/8”)
Alimentazione
Alimentazione unità interna
220-240V ~ 50Hz
220-240V ~ 50Hz
220-240V ~ 50Hz
220-240V ~ 50Hz
220-240V ~ 50Hz
220-240V ~ 50Hz
220-240V ~ 50Hz
Unità interna
Diametro scarico condensa
mm
25,0
25,0
25,0
25,0
25,0
25,0
25,
0
(1)
(2)
(3)
(4)
(5)
Ra
ffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m
.
Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m
.
La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40
.
Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744
.
Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale
.
MVA711C
MVA801C
MVA901C
MVA1001C
MVA1121C
MVA1251C
MVA1401C
MVA1601
C
Prestazioni in raffrescamento nominali
Potenza frigorifera (1)
kW
7,10
8,00
9,00
10,00
11,20
12,50
14,00
16,00
Prestazioni in riscaldamento nominal
i
Potenza termica (2)
kW
8,00
9,00
10,00
11,20
12,50
14,00
16,00
18,0
0
Dati elettric
i
Potenza nominale assorbita (3)
W
60
85
85
85
115
115
115
170
Ventilatore
Tipo
tipo
Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverte
r
Portata d’aria
Minima
Media
Massima
m³/h
850
900
900
900
1.100
1.100
1.100
1.43
0
m³/h
950
1.000
1.000
1.000
1.300
1.300
1.300
1.800
m³/h
1.150
1.250
1.250
1.250
1.650
1.650
1.650
2.00
0
Potenza sonora (4)
Minima
Media
Massima
dB(A)
45,0
48,0
48,0
48,0
53,0
53,0
53,0
54,0
dB(A)
48,0
51,0
51,0
51,0
55,0
55,0
55,0
60,0
dB(A)
51,0
53,0
53,0
53,0
57,0
57,0
57,0
63,0
Pressione sonora (5
)
Minima
Media
Massima
dB(A)
31,0
34,0
34,0
34,0
39,0
39,0
39,0
42,
0
dB(A)
34,0
37,0
37,0
37,0
41,0
41,0
41,0
48,
0
dB(A)
37,0
39,0
39,0
39,0
43,0
43,0
43,0
51,0
Tubazioni frigorifere
Diametro attacchi frigoriferi liquido
mm (inch)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
Diametro attacchi frigoriferi gas
mm (inch)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
19,05 (3/4”)
Alimentazion
e
Alimentazione unità interna
220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50H
z
Unità interna
Diametro scarico condensa
mm
25,0
25,0
25,0
25,0
25,0
25,0
25,0
25,0
(1)
(2)
(3)
(4)
(5)
Ra
ffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m
.
La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744
.
Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.
S
I
S
T
E
M
I
V
R
F
1036
www.aermec.com
MVBM_I_UN50_05