MVA_FS

MVA220FS

MVA280FS

MVA360FS

MVA450FS

MVA500F

S

Prestazioni in ra

ffrescamento nominal

i

Potenza frigorifera (1)

kW

2,20

2,80

3,60

4,50

5,00

Prestazioni in riscaldamento nominal

i

Potenza termica (2)

kW

2,50

3,20

4,00

5,00

5,5

0

Dati elettrici

Portata d’ari

a

Potenza nominale assorbita (3)

W

15

15

20

40

40

Ventilatore

Tipo

tipo

Centrifugo inverter

Centrifugo inverter

Centrifugo inverter

Centrifugo inverter

Centrifugo inverte

r

m³/h

270

270

310

500

500

m³/h

320

320

400

600

60

0

Massima

m³/h

400

400

480

680

68

0

Minima

Media

Potenza sonora (4

)

Minima

Media

Massima

dB(A)

37,0

37,0

42,0

49,0

49,

0

dB(A)

43,0

43,0

47,0

53,0

53,

0

dB(A)

48,0

48,0

50,0

56,0

56,

0

Pressione sonora (5

)

Minima

Media

Massima

Tubazioni frigorifere

dB(A)

27,0

27,0

32,0

39,0

39,

0

dB(A)

33,0

33,0

37,0

43,0

43,

0

dB(A)

38,0

38,0

40,0

46,0

46,

0

Diametro attacchi frigoriferi liquido

mm (inch)

6,35 (1/4”)

6,35 (1/4”)

6,35 (1/4”)

6,35 (1/4”)

6,35 (1/4”

)

Diametro attacchi frigoriferi gas

mm (inch)

9,52 (3/8”)

9,52 (3/8”)

12,7 (1/2”)

12,7 (1/2”)

12,7 (1/2”

)

Alimentazion

e

Alimentazione unità interna

220-240V ~ 50Hz

220-240V ~ 50Hz

220-240V ~ 50Hz

220-240V ~ 50Hz

220-240V ~ 50H

z

Unità intern

a

Diametro scarico condensa

mm

17,2

17,2

17,2

17,2

17,

2

(1)

(2)

(3)

(4)

(5)

MVA_V

Ra

ffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.

Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m

.

La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.

Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744

.

Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.

MVA1000V

MVA1400V

Prestazioni in raffrescamento nominali

Potenza frigorifera (1)

kW

10,00

14,0

0

Prestazioni in riscaldamento nominali

Potenza termica (2)

kW

11,00

15,0

0

Dati elettric

i

Potenza nominale assorbita (3)

W

200

200

Ventilatore

Tipo

tipo

Centrifugo inverter

Centrifugo inverte

r

Portata d’ari

a

Minima

m³/h

1.400

1.40

0

Media

m³/h

1.600

1.60

0

Massima

m³/h

1.850

1.85

0

Potenza sonora (4)

Minima

dB(A)

56,0

56,0

Media

dB(A)

58,0

58,

0

Massima

dB(A)

60,0

60,

0

Pressione sonora (5)

Minima

dB(A)

46,0

46,0

Media

dB(A)

48,0

48,

0

Massima

dB(A)

50,0

50,0

Tubazioni frigorifere

Diametro attacchi frigoriferi liquido

mm (inch)

9,52 (3/8”)

9,52 (3/8”)

Diametro attacchi frigoriferi gas

mm (inch)

15,9 (5/8”)

15,9 (5/8”)

Alimentazion

e

Alimentazione unità interna

220-240V ~ 50Hz

220-240V ~ 50Hz

Unità intern

a

Diametro scarico condensa

mm

31,0

31,

0

(1)

(2)

(3)

(4)

(5)

Ra

ffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.

Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m

.

La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.

Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744

.

Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale

.

S

I

S

T

E

M

I

V

R

F

1038

www.aermec.com

MVBM_I_UN50_05