MVA_DV
MVA220DV
MVA280DV
MVA360DV
MVA450DV
MVA560DV
MVA630DV
MVA710D
V
Prestazioni in ra
ffrescamento nominal
i
Potenza frigorifera (1)
Prestazioni in riscaldamento nominali
Potenza termica (2)
kW
2,20
2,80
3,60
4,50
5,60
6,30
7,1
0
kW
2,50
3,20
4,00
5,00
6,30
7,10
8,0
0
Dati elettric
i
Ventilatore
Tipo
Portata d’aria
Minima
Media
Massima
Potenza nominale assorbita (3)
W
35
35
43
45
80
80
9
0
tipo
Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverte
r
m³/h
250
250
350
400
600
600
700
m³/h
350
350
450
500
750
750
90
0
m³/h
450
450
550
650
900
900
1.100
Pressione statica utile
Nominale
Minima
Massima
Pa
10
10
10
15
15
15
15
Pa
0
0
0
0
0
0
0
Pa
40
40
40
60
60
60
60
Potenza sonora (4)
Minima
Media
Massima
dB(A)
35,0
35,0
38,0
38,0
40,0
40,0
43,
0
dB(A)
38,0
38,0
41,0
41,0
43,0
43,0
45,
0
dB(A)
40,0
40,0
43,0
43,0
45,0
45,0
47,
0
Pressione sonora (5)
Minima
Media
Massima
Tubazioni frigorifer
e
dB(A)
25,0
25,0
28,0
28,0
30,0
30,0
33,
0
dB(A)
28,0
28,0
31,0
31,0
33,0
33,0
35,0
dB(A)
30,0
30,0
33,0
33,0
35,0
35,0
37,0
Diametro attacchi frigoriferi liquido
mm (inch)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
Diametro attacchi frigoriferi gas
mm (inch)
9,52 (3/8”)
9,52 (3/8”)
12,7 (1/2”)
12,7 (1/2”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
Alimentazion
e
220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50H
z
Alimentazione unità interna
Unità intern
a
Diametro scarico condensa
mm
25,0
25,0
25,0
25,0
25,0
25,0
25,
0
(1)
(2)
(3)
(4)
(5)
Ra
ffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m
.
Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40
.
Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744
.
Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale
.
MVA_CS
MVA151CS
MVA181CS
MVA221CS
MVA281CS
MVA361CS
MVA451CS
MVA501CS
MVA561C
S
Prestazioni in raffrescamento nominal
i
Potenza frigorifera (1)
kW
1,50
1,80
2,20
2,80
3,60
4,50
5,00
5,60
Prestazioni in riscaldamento nominal
i
Potenza termica (2)
kW
1,80
2,20
2,50
3,20
4,00
5,00
5,60
6,3
0
Dati elettrici
Potenza nominale assorbita (3)
W
30
30
30
30
30
45
45
45
Ventilatore
Tipo
tipo
Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter Centrifugo inverter
Portata d’aria
Minima
Media
Massima
m³/h
370
370
370
420
480
560
560
56
0
m³/h
420
420
460
480
550
650
650
650
m³/h
460
460
500
570
620
730
730
730
Potenza sonora (4)
Minima
Media
Massima
dB(A)
39,0
39,0
39,0
42,0
45,0
53,0
43,0
53,0
dB(A)
44,0
44,0
45,0
47,0
49,0
55,0
55,0
55,
0
dB(A)
47,0
47,0
50,0
50,0
52,0
57,0
57,0
57,0
Pressione sonora (5
)
Minima
Media
Massima
dB(A)
25,0
25,0
25,0
28,0
31,0
39,0
39,0
39,
0
dB(A)
30,0
30,0
31,0
33,0
35,0
41,0
41,0
41,
0
dB(A)
33,0
33,0
36,0
36,0
38,0
43,0
43,0
43,0
Tubazioni frigorifere
Diametro attacchi frigoriferi liquido
mm (inch)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
9,52 (3/8”)
Diametro attacchi frigoriferi gas
mm (inch)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
12,7 (1/2”)
12,7 (1/2”)
12,7 (1/2”)
15,9 (5/8”)
Alimentazion
e
Alimentazione unità interna
220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz
Unità interna
Diametro scarico condensa
mm
25,0
25,0
25,0
25,0
25,0
25,0
25,0
25,
0
(1)
(2)
(3)
(4)
(5)
Ra
ffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m
.
La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744
.
Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale
.
S
I
S
T
E
M
I
V
R
F
MVBM_I_UN50_0
5
www.aermec.com
1035