TM
Venti-
latori
Condizi.
di prova
Unità
OP-UCGC003
OP-UCGC004
OP-UCGC005
OP-UCGC006
OP-MCGC006
OP-UCGC007
OP-UCGC008
OP-MCGC007
Vers.
Codice
A00
114X0104
A01
114X0105
A04
114X0107
A00
114X0108
A01
114X0109
A04
114X0111
A00
114X0112
A01
114X0113
A04
114X0115
A00
114X0200
A01
114X0201
A04
114X0203
A00
114X0228
A00
114X0216
A01
114X0217
A04
114X0227
A00
114X0224
A01
114X0225
A04
114X0227
A00
114X0244
A00
114X0232
A01
114X0233
A00
114X0352
A04
114X0223
A00
114X0336
A01
114X0337
A04
114X0339
A00
114X0340
A01
114X0341
A04
114X0343
A00
114X0448
A01
114X0449
A04
114X0451
A00
114X0556
A01
114X0557
A04
114X0559
A00
114X0564
A01
114X0565
A04
114X0567
A00
114X0568
A01
114X0773
A01
114X0781
CECOMAF
32 °C
32 °C
0K
Codice
elettrico
G
G
G
G
A
G
G
A
G
A
G
G
G
G
G
G
G
G
G
Com-
pressore
TL3GX
TL4GX
TL5GX
FR6GX
NL6.1MF
FR7.5GX
FR8.5GX
NL7.3MF
FR10GX
NL8.4MF
SC10GX
FR11GX
SC12GX
SC15GX
SC18GX
SC21GX
SC21MF
GS26MFX
GS34MFX
Temp.
amb.
[°C] -30 °C
27
50
32
40
38
40
43
30
27
70
32
60
38
50
43
40
27
80
32
70
38
70
43
60
80
Assorb. elettrico
[W] alla temp. di
evap -10 °C
120
140
170
190
200
210
250
240
280
270
300
330
370
460
520
600
630
770
980
Condizione di test
Codice elettrico
Versione
CECOMAF OP-UCGC010
200
180
160
140
Temperatura ambiente:
Temperatura del gas
di aspirazione:
Sottoraffreddamento:
A: compressore 230 V / monofase / 50+60 Hz,
ventilatore 230 V / monofase / 50 + 60 Hz
G: compressore 230 V / monofase / 50 Hz,
ventilatore 230 V / monofase / 50 Hz
A00: senza valvole e ricevitore per capillari
A01: con ricevitore, 2 valvole di arresto, staffe e tubi di
rame per KP
A04: A01 + KP17WB + kit FSA + cavo alimentazione
RGT20
OP-MCGC008
OP-UCGC010
OP-UCGC011
OP-UCGC012
OP-UCGC015
OP-UCGC018
OP-UCGC021
OP-MCGC021
OP-UCGC026
OP-UCGC034
RGT20
32 °C
20 °C
0 K
27
160
32
140
38
110
43
90
27
170
32
150
38
130
43
120
27
210
32
180
38
150
43
120
27
–
32
–
38
–
43
–
27
–
32
–
38
–
43
–
27
–
32
–
38
–
43
–
27
–
32
–
38
–
43
–
27
–
32
–
38
–
43
–
27
–
32
–
38
–
43
–
230
210
170
140
250
230
200
180
290
260
220
190
320
290
240
190
410
370
320
290
490
450
400
360
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
830
1000
–
770
940
–
710
870
–
650
810
–
1030
1260
1520
960
1180
1430
870
1080
1320
800
1000
1230
1170
1440
1740
1110
1360
1640
1020
1250
1510
950
1160
1400
1390
1670
2000
1300
1570
1890
1190
1460
1760
1120
1380
1670
1670
2010
2390
1570
1900
2270
1450
1760
2110
1330
1630
1970
1670
2030
2440
1570
1910
2310
1450
1780
2150
1360
1660
2010
2240
2750
–
2080
2550
–
1900
2320
–
1750
2140
–
2860
3480
–
2680
3270
–
2470
3020
–
2290
2810
–
Assorbimento elettrico alla temp. ambiente di 32 °C
27
100
32
90
38
70
43
50
90
27
–
–
32
–
–
38
–
–
43
–
–
27
110
32
100
38
80
43
70
27
140
32
130
38
110
43
90
27
–
–
32
–
–
38
–
–
43
–
–
27
150
32
130
38
110
43
100
27
–
–
32
–
–
38
–
–
43
–
–
-25 °C
-20 °C
90
80
70
60
120
110
90
80
140
130
120
110
190
170
150
130
200
180
170
150
200
190
170
150
250
230
200
180
250
230
210
190
270
240
220
200
290
270
240
220
310
280
240
210
330
310
270
250
390
350
310
270
440
410
360
310
550
500
440
410
660
60
540
480
680
640
580
540
860
800
730
660
1150
1060
950
860
-10 °C
150
140
130
110
190
180
160
150
230
220
200
190
310
290
260
240
330
310
280
260
340
320
290
270
400
380
340
310
410
380
350
320
430
400
370
340
470
440
400
370
490
450
400
370
550
500
450
410
660
610
540
490
750
710
650
600
910
840
760
710
1100
1020
930
840
1090
1030
940
880
1440
1340
1220
1120
1870
1740
1590
1460
0 °C
240
220
200
180
300
280
250
240
360
340
310
290
470
440
410
380
520
490
440
410
530
490
460
430
620
590
540
500
640
590
540
500
670
630
580
540
730
680
620
580
710
660
610
5 °C
290
270
250
220
360
340
310
10 °C
350
330
300
270
430
410
–
70
60
50
40
90
80
70
60
110
100
90
–
–
440
530
410
500
380
460
360
430
580
700
540
660
500
610
470
570
640
770
600
720
550
660
500
610
640
780
610
740
560
690
530
640
750
910
720
860
660
800
620
750
780
940
730
880
670
810
620
750
820
990
770
930
710
860
660
–
890
1080
830
1010
760
930
710
860
820
950
780
910
730
–
140
120
110
150
140
120
110
190
170
150
130
Campo resa frigorifera in [W]
a temperatura di evaporazione [oC]