Dispersione termica q [W/m] per un tubo
PREMAN
T
Valore U
Temperatura media tra MA/RI TB [°C]
W/mK
50 °C
60 °C
70 °C
80 °C
90 °C
100 °C
110 °C
120 °C
130 °C
26.
9
33.
7
42.
4
- 110
- 110
- 125
0.1110
4.4
5.5
6.7
7.8
8.9
10.0
11.1
12.2
13.3
0.1311
5.2
6.6
7.9
9.2
10.5
11.8
13.1
14.4
15.7
0.1424
5.7
7.1
8.5
10.0
11.4
12.8
14.2
15.7
17.1
48.
3
60.
3
76.
1
- 125
- 140
- 160
0.1606
6.4
8.0
9.6
11.2
12.8
14.5
16.1
17.7
19.3
0.1794
7.2
9.0
10.8
12.6
14.4
16.1
17.9
19.7
21.5
0.2009
8.0
10.0
12.1
14.1
16.1
18.1
20.1
22.1
24.1
88.
9
114.3
139.7
- 180
- 225
- 250
0.2105
8.4
10.5
12.6
14.7
16.8
18.9
21.0
23.2
25.3
0.2193
8.8
11.0
13.2
15.4
17.5
19.7
21.9
24.1
26.3
0.2530
10.1
12.7
15.2
17.7
20.2
22.8
25.3
27.8
30.4
168.3
219.1
273.0
- 280
- 355
- 450
0.2870
11.5
14.3
17.2
20.1
23.0
25.8
28.7
31.6
34.4
0.3047
12.2
15.2
18.3
21.3
24.4
27.4
30.5
33.5
36.6
0.2985
11.9
14.9
17.9
20.9
23.9
26.9
29.9
32.8
35.8
323.9
355.6
406.4
- 500
- 560
- 630
0.3412
13.6
17.1
20.5
23.9
27.3
30.7
34.1
37.5
40.9
0.3297
13.2
16.5
19.8
23.1
26.4
29.7
33.0
36.3
39.6
0.3425
13.7
17.1
20.5
24.0
27.4
30.8
34.2
37.7
41.1
457.2
508.0
610.0
- 710
- 800
- 900
0.3899
15.6
19.5
23.4
27.3
31.2
35.1
39.0
42.9
46.8
0.3357
13.4
16.8
20.1
23.5
26.9
30.2
33.6
36.9
40.3
0.3879
15.5
19.4
23.3
27.2
31.0
34.9
38.8
42.7
46.5
711.0
813.0
914.0
-
-
-
1000
1100
1200
0.4381
17.5
21.9
26.3
30.7
35.0
39.4
43.8
48.2
52.6
0.4899
19.6
24.5
29.4
34.3
39.2
44.1
49.0
53.9
58.8
0.5405
21.6
27.0
32.4
37.8
43.2
48.6
54.0
59.4
64.9
Tipo di posa:
2 tubi interrati
Distanza fra i tubi:
a =
0.20 m
Temperatura del terreno:
TE =
10 °
C
Altezza reinterro:
H =
0.8 m
Conducibilità del suolo:
lE =
1.2 W/m
K
Conducibilità della guaina in PE:
lPE=
0.4 W/mK
Conducibilità della schiuma PUR:
lPUR=
0.0270 W/mK
a
H
l
E
TE
Dispersione termica in esercizio
:
q = U · (TB - TE) [W/m]
U = Coe
fficiente di trasmittanza termica [W/mK]
TB = Temperatura media tra MA/RI TB [°C]
TE = Temperatura del terreno media [°C
]
13.01.2026 | Con riserva di modifiche tecniche.