Taglia
Carica refrigerante
circuito 2 (1)
1402
1602
1802
2002
2202
2352
2502
2652
2802
3002
3202
3402
3602
390
2
°
kg
24,0
25,0
25,0
41,0
33,0
38,0
37,0
37,5
35,0
50,0
48,0
46,0
46,0
59,0
A
kg
28,0
34,0
29,5
36,0
34,0
49,0
40,5
45,0
47,5
48,0
50,0
55,0
60,0
81,0
E
kg
29,0
31,5
41,0
40,0
40,0
45,0
45,0
52,0
53,0
53,0
59,0
59,0
74,0
77,0
L
kg
27,0
28,0
37,0
36,0
34,0
40,0
40,5
43,0
46,0
52,0
50,0
55,0
58,0
72,0
N
kg
36,0
38,0
34,0
49,0
49,0
56,0
56,0
64,0
64,0
69,0
57,0
77,0
81,0
92,0
U
kg
32,0
34,0
36,0
41,5
46,0
53,0
54,0
52,0
48,5
65,0
59,0
62,0
63,0
90,
0
Carica refrigerant
e
circuito 3 (1)
°,A,E,L,N,U
kg
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Potenziale riscalda-
mento globale (GWP) °,A,E,L,N,U
1.3
7
°
tCO2eq
0,06
0,06
0,07
0,08
0,08
0,09
0,09
0,09
0,10
0,11
0,12
0,12
0,13
0,14
A
tCO2eq
0,08
0,08
0,09
0,10
0,11
0,11
0,12
0,13
0,13
0,14
0,14
0,16
0,16
0,1
8
E
tCO2eq
0,08
0,09
0,10
0,11
0,12
0,13
0,13
0,14
0,15
0,15
0,16
0,17
0,18
0,19
CO2 equivalent
e
L
tCO2eq
0,07
0,07
0,08
0,08
0,10
0,10
0,10
0,11
0,12
0,12
0,13
0,14
0,15
0,16
N
tCO2eq
0,10
0,10
0,12
0,12
0,13
0,14
0,14
0,15
0,16
0,16
0,17
0,18
0,20
0,21
U
tCO2eq
0,09
0,09
0,11
0,11
0,12
0,13
0,13
0,15
0,15
0,16
0,16
0,18
0,18
0,20
Scambiatore lato utenz
a
Tipo
°,A,E,L,N,U
tipo
Fascio tubiero
Numero
°,A,E,L,N,U
n°
1
1
1
1
1
1
1
1
1
1
1
1
1
1
(1)
La carica riportata in tabella è un valore stimato e preliminare. Il valore finale della carica di refrigerante è riportato nella targhetta tecnica dell’unità. Per maggiori informazioni contattare sede
.
Taglia
4202
4502
4802
5202
5602
6002
6402
6503
6703
6903
7203
8403
960
3
Compressore
Tipo
°,A,E,L,N,U
tipo
Vit
e
°,A,L
n°
2
2
2
2
2
2
2
3
3
3
3
3
3
Numero
E,U
n°
2
2
2
2
2
2
2
3
3
3
3
-
-
N
n°
2
2
2
2
2
2
2
3
-
-
-
-
-
°,A,L
n°
2
2
2
2
2
2
2
3
3
3
3
3
3
Circuiti
E,U
n°
2
2
2
2
2
2
2
3
3
3
3
-
-
N
n°
2
2
2
2
2
2
2
3
-
-
-
-
-
Refrigerante
°,A,E,L,N,U
tipo
R1234ze
°
kg
52,0
55,0
55,0
63,0
65,0
62,0
70,0
67,0
55,0
78,0
62,0
99,0
112,0
A,L
kg
62,0
67,0
67,0
70,0
106,0
82,0
82,0
74,0
81,0
85,0
70,0
106,0
80,0
Carica refrigerante
circuito 1 (1)
E
kg
70,0
89,0
80,0
100,0
113,0
86,0
95,0
77,0
89,0
89,0
100,0
-
-
N
kg
92,0
99,0
110,0
114,0
128,0
128,0
138,0
85,0
-
-
-
-
-
U
kg
70,0
89,0
80,0
85,0
113,0
86,0
95,0
77,0
89,0
89,0
100,0
-
-
°
kg
59,0
64,0
64,0
70,0
71,0
73,0
80,0
74,0
61,0
85,0
70,0
99,0
112,0
A
kg
70,0
78,0
78,0
82,0
106,0
99,0
99,0
81,0
81,0
92,0
75,0
106,0
95,0
Carica refrigerante
circuito 2 (1)
E
kg
85,0
96,0
90,0
110,0
113,0
98,0
97,0
85,0
89,0
96,0
100,0
-
-
L
kg
70,0
79,0
78,0
82,0
106,0
99,0
99,0
81,0
81,0
92,0
75,0
106,0
95,0
N
kg
92,0
107,0
110,0
124,0
128,0
138,0
138,0
92,0
-
-
-
-
-
U
kg
85,0
96,0
90,0
103,0
113,0
98,0
97,0
85,0
89,0
96,0
100,0
-
-
°
kg
-
-
-
-
-
-
-
74,0
65,0
85,0
80,0
99,0
112,0
Carica refrigerante
circuito 3 (1)
A,L
kg
-
-
-
-
-
-
-
81,0
81,0
92,0
75,0
106,0
85,0
E,U
kg
-
-
-
-
-
-
-
85,0
89,0
96,0
100,0
-
-
N
kg
-
-
-
-
-
-
-
92,0
-
-
-
-
-
Potenziale riscalda -
mento globale (GWP) °,A,E,L,N,U
1.37
°
tCO2eq
0,15
0,16
0,17
0,18
0,19
0,20
0,22
0,21
0,22
0,24
0,25
0,29
0,3
3
A
tCO2eq
0,18
0,20
0,21
0,22
0,24
0,25
0,27
0,27
0,28
0,30
0,31
0,35
0,40
E
tCO2eq
0,21
0,22
0,24
0,25
0,27
0,28
0,30
0,30
0,32
0,33
0,35
-
-
CO2 equivalent
e
L
tCO2eq
0,17
0,18
0,19
0,20
0,22
0,23
0,24
0,24
0,25
0,28
0,28
0,32
0,37
N
tCO2eq
0,22
0,25
0,26
0,28
0,30
0,31
0,32
0,32
-
-
-
-
-
U
tCO2eq
0,21
0,22
0,24
0,25
0,27
0,29
0,31
0,30
0,32
0,34
0,36
-
-
Scambiatore lato utenz
a
Tipo
°,A,E,L,N,U
tipo
Fascio tubiero
°
n°
1
1
1
1
1
1
1
1
1
1
1
1
1
A,L
n°
1
1
1
1
1
1
1
2
2
2
2
2
2
Numero
E,U
n°
1
1
1
1
2
2
2
2
2
2
2
-
-
N
n°
1
2
2
2
2
2
2
2
-
-
-
-
-
(1)
La carica riportata in tabella è un valore stimato e preliminare. Il valore
finale della carica di refrigerante è riportato nella targhetta tecnica dell’unità. Per maggiori informazioni contattare sede
.
DATI VENTILATORI
Taglia
Ventilator
e
Tipo
Numero
1402
1602
1802
2002
2202
2352
2502
2652
2802
3002
3202
3402
3602
390
2
°,A,E,L,N,U
tipo
Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale
°
n°
6
6
6
8
8
8
8
8
8
10
10
10
10
12
A,L
n°
8
8
8
8
10
10
10
12
12
12
12
14
14
16
E,U
n°
8
8
10
10
10
12
12
14
14
14
14
16
16
18
N
n°
10
10
12
12
12
14
14
16
16
16
16
18
20
22
A
R
I
A
-
A
C
Q
U
A
NSG-1402-9603-CO_I_CE50_13
www.aermec.com
637