Taglia

Carica refrigerante

circuito 2 (1)

1402

1602

1802

2002

2202

2352

2502

2652

2802

3002

3202

3402

3602

390

2

°

kg

24,0

25,0

25,0

41,0

33,0

38,0

37,0

37,5

35,0

50,0

48,0

46,0

46,0

59,0

A

kg

28,0

34,0

29,5

36,0

34,0

49,0

40,5

45,0

47,5

48,0

50,0

55,0

60,0

81,0

E

kg

29,0

31,5

41,0

40,0

40,0

45,0

45,0

52,0

53,0

53,0

59,0

59,0

74,0

77,0

L

kg

27,0

28,0

37,0

36,0

34,0

40,0

40,5

43,0

46,0

52,0

50,0

55,0

58,0

72,0

N

kg

36,0

38,0

34,0

49,0

49,0

56,0

56,0

64,0

64,0

69,0

57,0

77,0

81,0

92,0

U

kg

32,0

34,0

36,0

41,5

46,0

53,0

54,0

52,0

48,5

65,0

59,0

62,0

63,0

90,

0

Carica refrigerant

e

circuito 3 (1)

°,A,E,L,N,U

kg

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Potenziale riscalda-

mento globale (GWP) °,A,E,L,N,U

1.3

7

°

tCO2eq

0,06

0,06

0,07

0,08

0,08

0,09

0,09

0,09

0,10

0,11

0,12

0,12

0,13

0,14

A

tCO2eq

0,08

0,08

0,09

0,10

0,11

0,11

0,12

0,13

0,13

0,14

0,14

0,16

0,16

0,1

8

E

tCO2eq

0,08

0,09

0,10

0,11

0,12

0,13

0,13

0,14

0,15

0,15

0,16

0,17

0,18

0,19

CO2 equivalent

e

L

tCO2eq

0,07

0,07

0,08

0,08

0,10

0,10

0,10

0,11

0,12

0,12

0,13

0,14

0,15

0,16

N

tCO2eq

0,10

0,10

0,12

0,12

0,13

0,14

0,14

0,15

0,16

0,16

0,17

0,18

0,20

0,21

U

tCO2eq

0,09

0,09

0,11

0,11

0,12

0,13

0,13

0,15

0,15

0,16

0,16

0,18

0,18

0,20

Scambiatore lato utenz

a

Tipo

°,A,E,L,N,U

tipo

Fascio tubiero

Numero

°,A,E,L,N,U

n°

1

1

1

1

1

1

1

1

1

1

1

1

1

1

(1)

La carica riportata in tabella è un valore stimato e preliminare. Il valore finale della carica di refrigerante è riportato nella targhetta tecnica dell’unità. Per maggiori informazioni contattare sede

.

Taglia

4202

4502

4802

5202

5602

6002

6402

6503

6703

6903

7203

8403

960

3

Compressore

Tipo

°,A,E,L,N,U

tipo

Vit

e

°,A,L

n°

2

2

2

2

2

2

2

3

3

3

3

3

3

Numero

E,U

n°

2

2

2

2

2

2

2

3

3

3

3

-

-

N

n°

2

2

2

2

2

2

2

3

-

-

-

-

-

°,A,L

n°

2

2

2

2

2

2

2

3

3

3

3

3

3

Circuiti

E,U

n°

2

2

2

2

2

2

2

3

3

3

3

-

-

N

n°

2

2

2

2

2

2

2

3

-

-

-

-

-

Refrigerante

°,A,E,L,N,U

tipo

R1234ze

°

kg

52,0

55,0

55,0

63,0

65,0

62,0

70,0

67,0

55,0

78,0

62,0

99,0

112,0

A,L

kg

62,0

67,0

67,0

70,0

106,0

82,0

82,0

74,0

81,0

85,0

70,0

106,0

80,0

Carica refrigerante

circuito 1 (1)

E

kg

70,0

89,0

80,0

100,0

113,0

86,0

95,0

77,0

89,0

89,0

100,0

-

-

N

kg

92,0

99,0

110,0

114,0

128,0

128,0

138,0

85,0

-

-

-

-

-

U

kg

70,0

89,0

80,0

85,0

113,0

86,0

95,0

77,0

89,0

89,0

100,0

-

-

°

kg

59,0

64,0

64,0

70,0

71,0

73,0

80,0

74,0

61,0

85,0

70,0

99,0

112,0

A

kg

70,0

78,0

78,0

82,0

106,0

99,0

99,0

81,0

81,0

92,0

75,0

106,0

95,0

Carica refrigerante

circuito 2 (1)

E

kg

85,0

96,0

90,0

110,0

113,0

98,0

97,0

85,0

89,0

96,0

100,0

-

-

L

kg

70,0

79,0

78,0

82,0

106,0

99,0

99,0

81,0

81,0

92,0

75,0

106,0

95,0

N

kg

92,0

107,0

110,0

124,0

128,0

138,0

138,0

92,0

-

-

-

-

-

U

kg

85,0

96,0

90,0

103,0

113,0

98,0

97,0

85,0

89,0

96,0

100,0

-

-

°

kg

-

-

-

-

-

-

-

74,0

65,0

85,0

80,0

99,0

112,0

Carica refrigerante

circuito 3 (1)

A,L

kg

-

-

-

-

-

-

-

81,0

81,0

92,0

75,0

106,0

85,0

E,U

kg

-

-

-

-

-

-

-

85,0

89,0

96,0

100,0

-

-

N

kg

-

-

-

-

-

-

-

92,0

-

-

-

-

-

Potenziale riscalda -

mento globale (GWP) °,A,E,L,N,U

1.37

°

tCO2eq

0,15

0,16

0,17

0,18

0,19

0,20

0,22

0,21

0,22

0,24

0,25

0,29

0,3

3

A

tCO2eq

0,18

0,20

0,21

0,22

0,24

0,25

0,27

0,27

0,28

0,30

0,31

0,35

0,40

E

tCO2eq

0,21

0,22

0,24

0,25

0,27

0,28

0,30

0,30

0,32

0,33

0,35

-

-

CO2 equivalent

e

L

tCO2eq

0,17

0,18

0,19

0,20

0,22

0,23

0,24

0,24

0,25

0,28

0,28

0,32

0,37

N

tCO2eq

0,22

0,25

0,26

0,28

0,30

0,31

0,32

0,32

-

-

-

-

-

U

tCO2eq

0,21

0,22

0,24

0,25

0,27

0,29

0,31

0,30

0,32

0,34

0,36

-

-

Scambiatore lato utenz

a

Tipo

°,A,E,L,N,U

tipo

Fascio tubiero

°

n°

1

1

1

1

1

1

1

1

1

1

1

1

1

A,L

n°

1

1

1

1

1

1

1

2

2

2

2

2

2

Numero

E,U

n°

1

1

1

1

2

2

2

2

2

2

2

-

-

N

n°

1

2

2

2

2

2

2

2

-

-

-

-

-

(1)

La carica riportata in tabella è un valore stimato e preliminare. Il valore

finale della carica di refrigerante è riportato nella targhetta tecnica dell’unità. Per maggiori informazioni contattare sede

.

DATI VENTILATORI

Taglia

Ventilator

e

Tipo

Numero

1402

1602

1802

2002

2202

2352

2502

2652

2802

3002

3202

3402

3602

390

2

°,A,E,L,N,U

tipo

Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale Assiale

°

n°

6

6

6

8

8

8

8

8

8

10

10

10

10

12

A,L

n°

8

8

8

8

10

10

10

12

12

12

12

14

14

16

E,U

n°

8

8

10

10

10

12

12

14

14

14

14

16

16

18

N

n°

10

10

12

12

12

14

14

16

16

16

16

18

20

22

A

R

I

A

-

A

C

Q

U

A

NSG-1402-9603-CO_I_CE50_13

www.aermec.com

637