DATI TECNICI GENERALI

HM

I

Dati elettric

i

Corrente nominale assorbita (1)

Numero

Circuiti

Refrigerante

Carica refrigerante totale (2)

GWP

CO2 equivalente

Scambiatore lato utenza

Tipo

Numero

Attacchi (in/out)

Diametro (in)

HMI080

HMI100

HMI100T

HMI120

HMI120T

HMI140

HMI140T

HMI160

HMI160T

A

10,4

23,0

12,0

25,0

12,0

29,0

12,0

29,0

12,

0

Compressor

e

Tipo

tipo

Rotary D

C

Rotary DC

Rotary D

C

Rotary DC

Rotary D

C

Rotary DC

Rotary DC

Rotary DC

Rotary D

C

Inverte

r

Inverte

r

Inverte

r

Inverte

r

Inverte

r

Inverte

r

Inverte

r

Inverte

r

Inverte

r

n°

1

1

1

1

1

1

1

1

1

n°

1

1

1

1

1

1

1

1

1

tipo

R32

R32

R32

R32

R32

R32

R32

R32

R32

kg

0,90

2,20

2,20

2,20

2,20

2,20

2,20

2,20

2,20

675,0

675,0

675,0

675,0

675,0

675,0

675,0

675,0

675,0

tCO2eq

0,61

1,49

1,49

1,49

1,49

1,49

1,49

1,49

1,49

tipo

Piastre

Piastre

Piastre

Piastre

Piastre

Piastre

Piastre

Piastre

Piastre

n°

1

1

1

1

1

1

1

1

1

Tipo

Gas femmina Gas femmina Gas femmina Gas femmina Gas femmina Gas femmina Gas femmina Gas femmina Gas femmina

Ø

1”

1”

1”

1”

1”

1”

1”

1”

1

”

Ø

1”

1”

1”

1”

1”

1”

1”

1”

1”

tipo

Assiale

Assiale

Assiale

Assiale

Assiale

Assiale

Assiale

Assiale

Assiale

tipo

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Inverte

r

n°

1

1

1

1

1

1

1

1

1

m³/h

2.600

4.500

4.500

4.500

4.500

4.500

4.500

4.500

4.500

dB(A)

53,0

56,0

56,0

56,0

56,0

57,0

57,0

59,0

59,0

dB(A)

65,0

69,0

69,0

69,0

69,0

70,0

70,0

72,0

72,0

dB(A)

51,0

54,0

54,0

54,0

54,0

55,0

55,0

57,0

57,0

Alimentazione

V/Ph/Hz 220-240V

~

50H

z

220-240V ~

50H

z

380-415V 3N

~

50H

z

220-240V ~

50Hz

380-415V 3N

~

50Hz

220-240V

~

50H

z

380-415V 3N

~

50H

z

220-240V ~

50Hz

380-415V 3N

~

50H

z

(1)

(2)

La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.

La carica riportata in tabella è un valore stimato e preliminare. Il valore finale della carica di refrigerante è riportato nella targhetta tecnica dell'unità. Per maggiori informazioni contattare sede

.

HMI_1

Diametro (out)

Ventilatore

Tipo

A

R

I

A

-

A

C

Q

U

A

Motore ventilatore

Numero

Portata aria

Dati sonori misurati in funzionamento a fredd

o

Pressione sonora (1 m)

Dati sonori misurati in funzionamento a cald

o

Potenza sonora

Pressione sonora (1 m)

Alimentazion

e

Dati elettric

i

Corrente nominale assorbita (1)

Numero

Circuiti

Refrigerante

Carica refrigerante totale (2)

GWP

CO2 equivalente

Scambiatore lato utenza

Tipo

Numero

Alimentazion

e

(1)

(2)

HMI041 HMI061 HMI081 HMI081T HMI101 HMI101T HMI121 HMI121T HMI141 HMI141T HMI161 HMI161

T

A

11,0

11,0

23,0

8,0

25,0

9,0

29,0

11,5

30,0

12,0

30,0

12,

5

Compressor

e

Tipo

tipo

Rotativ

o

Rotativo

Rotativo

Rotativ

o

Rotativo

Rotativo

Rotativo

Rotativ

o

Rotativ

o

Rotativ

o

Rotativo

inverter

inverte

r

inverte

r

inverte

r

inverter

inverte

r

inverte

r

inverter

inverter

inverte

r

inverte

r

Rotativ

o

inverter

n°

1

1

1

1

1

1

1

1

1

1

1

1

n°

1

1

1

1

1

1

1

1

1

1

1

1

tipo

R32

R32

R32

R32

R32

R32

R32

R32

R32

R32

R32

R32

kg

0,95

0,95

1,60

1,60

1,60

1,60

2,20

2,20

2,20

2,20

2,20

2,20

675,0

675,0

675,0

675,0

675,0

675,0

675,0

675,0

675,0

675,0

675,0

675,

0

tCO2eq

0,64

0,64

1,08

1,08

1,08

1,08

1,49

1,49

1,49

1,49

1,49

1,49

tipo

Piastre

Piastre

Piastre

Piastre

Piastre

Piastre

Piastre

Piastre

Piastre

Piastre

Piastre

Piastr

e

n°

1

1

1

1

1

1

1

1

1

1

1

1

Attacchi (in/out)

Tipo

Ga

s

Gas

femmin

a

femmina

Ga

s

femmin

a

Ga

s

Ga

s

Ga

s

Ga

s

Ga

s

Ga

s

Ga

s

Ga

s

femmin

a

femmina

femmin

a

femmin

a

femmin

a

femmin

a

femmin

a

femmina

Ga

s

femmina

Ø

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

Ø

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

1”

tipo

Assiale

Assiale

Assiale

Assiale

Assiale

Assiale

Assiale

Assiale

Assiale

Assiale

Assiale

Assiale

tipo

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

n°

1

1

1

1

1

1

1

1

1

1

1

1

m³/h

3.200

3.200

5.800

5.800

5.800

5.800

5.051

5.051

5.051

5.051

5.051

5.051

dB(A)

58,0

58,0

68,0

68,0

68,0

68,0

68,0

68,0

68,0

68,0

68,0

68,

0

dB(A)

52,0

53,0

56,0

56,0

56,0

56,0

58,0

58,0

59,0

59,0

59,0

59,0

Alimentazione

V/Ph/Hz 230V ~

50Hz

230V ~

50H

z

230V

~

50Hz

400V 3N ~

50H

z

230V ~

50Hz

400V 3N

~

50Hz

230V

~

50H

z

400V 3N ~

50H

z

230V

~

50H

z

400V 3N

~

50Hz

230V

~

50H

z

400V 3N

~

50Hz

La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.

La carica riportata in tabella è un valore stimato e preliminare. Il valore

finale della carica di refrigerante è riportato nella targhetta tecnica dell'unità. Per maggiori informazioni contattare sede

.

Diametro (in)

Diametro (out)

Ventilatore

Tipo

Motore ventilatore

Numero

Portata aria

Dati sonori misurati in funzionamento a caldo

Potenza sonora

Pressione sonora (1 m)

352

www.aermec.com

HMI-HMI1-HP_I_UN50_00