FCZI400P

FCZI450

P

1

2

3

L

M

H

1

2

3

L

M

H

4,32

5,74

7,15

379

503

627

9

16

24

4,57

6,29

7,82

400

551

685

6

11

1

6

2,14

2,85

3,55

373

495

617

10

16

24

2,27

3,12

3,88

394

543

675

6

11

1

6

2,20

2,92

3,60

1,59

2,14

2,67

379

503

619

10

16

24

2,41

3,21

4,03

1,69

2,30

2,9

0

414

552

694

9

15

22

Centrifugo

Centrifugo

Inverter

Inverte

r

2

2

330

460

600

330

460

600

5

10

18

5

10

18

49

68

90

49

68

90

37,0

44,0

51,0

29,0

36,0

43,0

37,0

44,0

51,

0

29,0

36,0

43,

0

1,0

1,

4

3/4”

3/4

”

FCZI900P

1

2

3

L

M

H

FCZI950

P

1

2

3

L

M

H

10,77 13,35 15,14

945 1.171 1.328

12

17

22

11,20 14,42 17,1

0

982 1.264 1.50

0

16

24

33

5,35

6,64

7,53

930 1.152 1.307

12

17

22

5,57

7,17

8,5

0

967 1.245 1.47

6

15

24

33

4,29

5,00

6,91

2,97

3,78

5,68

738

860 1.189

10

12

22

5,77

7,32

8,60

3,80

4,87

5,78

992 1.259 1.47

9

15

22

30

Centrifugo

Centrifug

o

Inverter

Inverte

r

3

3

700

930 1.140

700

930 1.140

30

40

80

30

40

80

56

72

90

56

72

90

51,0

57,0

62,0

43,0

49,0

54,0

51,0

57,0

62,0

43,0

49,0

54,

0

1,8

2,

3

3/4”

3/4

”

V

E

N

T

I

L

C

O

N

V

E

T

T

O

R

I

DATI PRESTAZIONALI UNITÀ SENZA PREVALENZA (EUROVENT CERTIFICATO FC-H)

2 tub

i

FCZI200P

FCZI250P

FCZI300P

FCZI350P

1

2

3

1

2

3

Prestazioni in riscaldamento 70 °C / 60 °C (1

)

Potenza termica

kW

L

M

H

2,20

3,18

4,05

L

M

H

3,47

4,46

5,50

Portata acqua utenza

l/h

193

278

355

304

391

482

Perdita di carico lato utenza

Prestazioni in riscaldamento 45 °C / 40 °C (2)

Potenza termica

kPa

kW

7

15

23

1,09

1,58

2,01

7

12

18

1,72

2,21

2,73

Portata acqua utenza

l/h

190

274

350

299

385

475

Perdita di carico lato utenza

Prestazioni in raffreddamento 7 °C / 12 °C (3

)

Potenza frigorifera

kPa

kW

8

15

22

1,06

1,55

1,94

8

12

18

1,68

2,17

2,65

Potenza frigorifera sensibile

kW

Portata acqua utenza

l/h

Perdita di carico lato utenza

Ventilatore

Tipo

kPa

tipo

Motore ventilatore

tipo

Numero

n°

Portata aria

m³/h

Potenza assorbita

Segnale 0-10V

Dati sonori ventilconvettori (4)

Livello di potenza sonora

Livello di pressione sonora

dB(A)

Scambiatore di calore a pacco alettat

o

Contenuto acqua scambiatore principale

l

Diametro raccordi

Scambiatore principale

Ø

1

2

3

L

M

H

2,02

2,95

3,70

177

258

324

6

12

18

1,00

1,46

1,84

174

254

319

6

12

18

0,89

1,28

1,60

0,71

1,05

1,33

153

221

275

6

12

18

0,79

1,20

1,52

182

267

334

8

17

25

Centrifugo

Centrifugo

Inverter

Inverter

1

1

140

220

290

140

220

290

W

7

8

14

7

8

14

%

44

68

90

44

68

90

dB(A)

35,0

46,0

51,0

27,0

38,0

43,0

35,0

46,0

51,0

27,0

38,0

43,0

0,5

0,7

1/2”

FCZI500P

1

2

3

L

M

H

1/2”

FCZI550P

1

2

3

L

M

H

1

2

3

L

M

H

3,77

4,92

6,15

330

431

539

8

14

20

1,87

2,44

3,06

325

425

531

8

14

20

1,26

1,65

2,04

288

374

456

8

13

18

1,89

2,46

3,02

1,33

1,76

2,18

350

460

560

11

18

25

Centrifugo

Centrifugo

Inverter

Inverter

2

2

260

350

450

260

350

450

5

7

13

5

7

13

52

70

90

52

70

90

34,0

41,0

48,0

26,0

33,0

40,0

34,0

41,0

48,0

26,0

33,0

40,0

0,8

1,0

3/4”

FCZI700P

1

2

3

L

M

H

3/4”

FCZI750P

1

2

3

L

M

H

Prestazioni in riscaldamento 70 °C / 60 °C (1)

Potenza termica

Portata acqua utenza

Perdita di carico lato utenza

kW

l/h

kPa

5,27

7,31

8,50

462

641

745

12

21

28

5,82

8,34

9,75

510

731

855

10

20

26

8,10

9,80 11,00

710

860

964

9,10 11,30 12,50

798

991 1.096

10

15

18

Prestazioni in riscaldamento 45 °C / 40 °C (2

)

Potenza termica

Portata acqua utenza

Perdita di carico lato utenza

kW

l/h

kPa

2,62

3,63

4,22

455

631

734

12

21

28

2,89

4,14

4,85

502

720

842

10

20

26

4,52

5,62

6,21

786

975 1.079

10

14

18

Prestazioni in raffreddamento 7 °C / 12 °C (3

)

Potenza frigorifera

Potenza frigorifera sensibile

Portata acqua utenza

Perdita di carico lato utenza

kW

kW

l/h

kPa

2,68

3,69

4,25

1,94

2,73

3,18

460

634

731

13

22

29

2,91

4,13

4,79

2,07

2,98

3,49

501

711

824

12

22

28

2,99

3,76

4,30

675

841

946

16

24

30

4,27

5,34

6,14

3,20

4,05

4,72

734

918 1.056

10

14

18

Ventilatore

Tipo

Motore ventilatore

Numero

Portata aria

Potenza assorbita

Segnale 0-10V

tipo

Centrifugo

Centrifugo

tipo

Inverter

Inverter

n°

2

2

m³/h

400

600

720

400

600

720

W

7

18

31

4

10

19

%

50

74

90

50

74

90

Centrifugo

Centrifugo

Inverter

Inverter

3

3

700

930 1.140

700

930 1.140

30

40

80

30

40

80

56

72

90

56

72

90

Dati sonori ventilconvettori (4)

Livello di potenza sonora

Livello di pressione sonora

dB(A)

dB(A)

42,0

51,0

56,0

34,0

43,0

48,0

42,0

51,0

56,0

34,0

43,0

48,0

50,0

57,0

62,0

42,0

49,0

54,0

50,0

57,0

62,0

42,0

49,0

54,0

Scambiatore di calore a pacco alettat

o

Contenuto acqua scambiatore principale

l

1,0

1,4

1,2

1,6

Diametro raccordi

Scambiatore principale

Ø

3/4”

3/4”

3/4”

3/4”

(1)

Aria ambiente 20 °C b.s.; Acqua (in/out) 70 °C/60 °

C

(2)

Aria ambiente 20 °C b.s.; Acqua (in/out) 45 °C/40 °C; EUROVENT (listing FCU AERMEC 2025

)

(3)

Aria ambiente 27 °C b.s / 19 °C b.u.; Acqua (in/out) 7 °C/12 °C; EUROVENT (listing FCU AERMEC 2025

)

(4)

Aermec determina il valore della potenza sonora sulla base di misure effettuate in accordo con la normativa UNI EN 16583:15, nel rispetto della certi

ficazione Eurovent.

17

24

29

4,03

4,87

5,47

699

846

950

16

24

29

3,92

4,89

5,50

128

www.aermec.com

FCZI-P_I_UN50_14