Ventilatore

Portata aria

Pressione statica utile

Livello di potenza sonora (inlet + radiated)

Livello di potenza sonora (outlet)

FCYI700C

1

2

3

1

2

3

L

M

H

1

2

3

L

M

H

3,08

4,83

5,23

265

415

450

7

14

16

3,96

5,85

6,34

341

503

545

9

17

19

1,53

2,40

2,60

263

413

447

7

14

16

1,97

2,91

3,15

339

501

542

9

17

19

0,63

1,13

1,20

138

236

249

5

14

16

0,70

1,29

1,37

163

287

303

8

19

21

1,40

2,38

2,53

1,10

1,82

1,94

241

409

435

7

15

17

1,15

1,94

2,07

285

464

495

9

21

23

2,03

2,98

3,21

1,45

2,18

2,36

349

512

552

9

13

20

m³/h 123

240

257

123

240

257

225

390

424

225

390

424

300

470

515

300

470

515

Pa

13

50

57

13

50

57

16

50

59

16

50

59

20

50

60

20

50

60

dB(A) 37,0

57,0

59,0

37,0

57,0

59,0

36,0

50,0

53,0

36,0

50,0

53,0

43,0

53,0

55,0

43,0

53,0

55,0

dB(A) 33,0

53,0

55,0

33,0

53,0

55,0

32,0

47,0

49,0

32,0

47,0

49,0

39,0

49,0

52,0

39,0

49,0

52,0

W

7

27

31

7

27

31

10

30

40

10

30

40

14

38

48

14

38

48

Potenza assorbita

Diametro raccordi

Scambiatore principale

Ø

1/2”

1/2”

3/4”

3/4”

3/4”

3/4

”

Alimentazione

Alimentazione

V/Ph

/

Hz

230V~50H

z

FCYI500C

1

2

3

L

M

H

FCYI550C

1

2

3

L

M

H

FCYI750C

1

2

3

L

M

H

Prestazioni in riscaldamento 70 °C / 60 °C (1

)

Potenza termica

Portata acqua utenza

kW

l/h

Perdita di carico lato utenza

kPa

5,39

7,28

7,63

464

626

656

12

22

23

5,92

8,37

8,71

509

720

749

11

20

21

6,17

9,52

10,15

541

835

890

5

11

12

Prestazioni in riscaldamento 45 °C / 40 °C (2

)

Potenza termica

Portata acqua utenza

kW

l/h

Perdita di carico lato utenza

kPa

2,68

3,26

3,79

461

623

652

12

22

23

2,94

4,16

4,33

506

715

745

2,46

4,69

5,00

418

806

860

3

11

12

Prestazioni in ra

ffreddamento 7 °C / 12 °C (3

)

Potenza frigorifera

Potenza frigorifera sensibile

Portata acqua utenza

kW

kW

l/h

Perdita di carico lato utenza

kPa

2,73

3,68

3,84

1,98

2,73

2,85

469

633

660

13

22

25

511

714

741

13

22

25

2,20

4,00

4,30

1,71

3,00

3,20

378

688

739

7

18

20

2,60

4,41

4,70

1,90

3,30

3,50

447

760

818

4

11

12

Ventilator

e

Portata aria

m³/h

410

600

630

410

600

630

405

730

799

405

730

79

9

Pressione statica utile

Pa

23

50

55

23

50

55

15

50

60

15

50

6

0

Livello di potenza sonora (inlet + radiated)

dB(A)

45,0

56,0

57,0

45,0

56,0

57,0

38,0

55,0

58,0

41,0

55,0

58,0

Livello di potenza sonora (outlet)

dB(A)

42,0

52,0

52,0

42,0

52,0

52,0

34,0

51,0

54,0

36,0

51,0

54,0

Potenza assorbita

W

18

50

60

18

50

60

21

61

78

21

61

78

Diametro raccordi

Scambiatore principale

Ø

3/4”

Alimentazione

Alimentazione

V/Ph

/

Hz

230V~50H

z

(1)

(2)

(3)

Aria ambiente 20 °C b.s.; Acqua (in/out) 70 °C/60 °

C

Aria ambiente 20 °C b.s.; Acqua (in/out) 45 °C/40 °C; EUROVENT (listing FCU AERMEC 2025

)

Aria ambiente 27 °C b.s / 19 °C b.u.; Acqua (in/out) 7 °C/12 °C; EUROVENT (listing FCU AERMEC 2025

)

L

M

H

5,33

8,34

8,88

468

732

779

8

17

20

2,67

4,15

4,40

460

720

767

12

22

23

2,97

4,15

4,31

8

18

20

2,11

2,98

3,12

V

E

N

T

I

L

C

O

N

V

E

T

T

O

R

I

kit

filtro dimezzato

Modello

Ver

200

201

250

300

301

350

400

401

450

500

501

550

700

701

75

0

DFA2

C,U

•

•

•

DFA3

C,U

•

•

•

DFA5

C,U

•

•

•

•

•

•

DFA7

C

•

•

•

Protezione per flangi

a

Modello

PPB

2 tubi

Ver

200

201

250

300

301

350

400

401

450

500

501

550

700

701

750

C

•

•

•

•

•

•

•

•

•

•

•

•

•

•

•

U

•

•

•

•

•

•

•

•

•

•

•

•

DATI PRESTAZIONALI - FCYI_C E FCYI_U (CONFIGURAZIONE DEI BOCCAGLI AD H) 2 TUBI

FCYI300C

FCYI200C

FCYI250C

FCYI350C

FCYI400C

FCYI450

C

1

2

3

1

2

3

1

2

3

1

2

3

L

M

H

L

M

H

L

M

H

L

M

H

Prestazioni in riscaldamento 70 °C / 60 °C (1)

Potenza termica

kW

1,81

3,16

3,34

2,01

3,40

3,62

3,32

5,43

5,83

4,10

6,44

6,96

Portata acqua utenza

l/h

156

272

287

173

292

311

285

467

502

353

554

599

Perdita di carico lato utenza

kPa

6

13

16

7

17

19

7

17

19

5

12

13

Prestazioni in riscaldamento 45 °C / 40 °C (2)

Potenza termica

kW

0,90

1,57

1,66

1,00

1,69

1,80

1,65

2,70

2,90

2,04

3,20

3,46

Portata acqua utenza

l/h

155

270

288

172

291

308

284

464

499

351

550

595

Perdita di carico lato utenza

kPa

6

13

16

7

17

19

7

17

19

5

12

13

Prestazioni in raffreddamento 7 °C / 12 °C (3)

Potenza frigorifera

kW

0,80

1,37

1,45

0,95

1,67

1,76

1,66

2,70

2,88

2,22

3,28

3,5

5

Potenza frigorifera sensibile

kW

1,54

2,35

2,56

Portata acqua utenza

l/h

382

564

61

0

Perdita di carico lato utenza

kPa

8

16

18

100

www.aermec.com

FCY-I_I_UN50_07